$$G_c(s) = K_c\frac{s + z}{s + p}$$
| Lead ($z < p$) | Lag ($z > p$) | |
|---|---|---|
| Phase | Positive (adds phase) | Negative (small lag) |
| Main effect | More phase margin, faster response, wider bandwidth | Higher low-frequency gain, smaller steady-state error |
| Similar to | PD | PI |
| Drawback | Amplifies high-frequency noise | Slower response |
Maximum lead phase $\phi_m = \sin^{-1}\dfrac{1 - \alpha}{1 + \alpha}$ (with $\alpha = z/p < 1$) at $\omega_m = \sqrt{zp}$.
Lead design on the Bode plot
- Choose $K_c$ to meet the steady-state error requirement.
- Find the existing phase margin.
- Required lead $\phi_m$ = desired PM − existing PM + 5° to 12° margin.
- Find $\alpha$, place $\omega_m$ at the new gain crossover (where the uncompensated gain is $-10\log(1/\alpha)$ dB).
- Check the result.
Lead-lag combines both: the lag part fixes steady-state error and the lead part fixes transient response.
Design in MATLAB with margin() and bode(), then compare the step responses before and after compensation.